Total Organic Carbon Analyzer with method of Wet chemical oxidation by UV

Total Organic Carbon Analyzer with method of Wet chemical oxidation by UV

Precision Digital Rotating Viscometer, High Quality Viscometer,Digital Viscometer,Rotating Viscometer
INQUIRY PRECISE INQUIRY
Description

Overview
Quick Details
Place of Origin:
Guangdong, China (Mainland)
Brand Name:
A & E Lab
Model Number:
TOC-P01
Keywords:
total organic carbon analyzer
Parameters:
TC, TIC, TOC,NPOC
Detector:
NDIR
Digestion Mode:
Wet chemical oxidation by UV
Operation Mode:
PC Control
Application:
Liquid Sample, Gas Sample
Gas Requirement:
Nitrogen≥99.995%
Measurement Range:
0-10000mg/l
Detection Limit:
5μg/l
Repeatability:
3%
Packaging & Delivery
Packaging Details
total organic carbon analyzer:each set protected with a pp film, then put into strong carton box with operation manual.
Delivery Time
Shipped in 15 days after payment

Total Organic Carbon Analyzer with method of Wet chemical oxidation by UV

Product Description

General
TOC (Total Organic Carbon), which directly shows the total organic content, is regarded as a key factor to evaluate pollution potentials of organic compound in water.
After 3 years research and development, we successfully launch our new product: TOC. With our patent laws, our TOC can meet requirements for application in water analysis, environment monitoring, pharmaceutical production, quality control, processing control etc.
So far, we launch 2 models TOC: TOC-W01 (Catalytic combustion oxidation) and TOC-P01 (Wet chemical oxidation by UV) which are widely used for quality control of drinking water, industrial water, sewage and waste water. Meanwhile, it has wide application in monitoring of River, Lake, Sea and surface water.


Features
1.Signal management system with our own patent law which has great advantages of online setting, real-time monitoring, self testing and flow speed control to ensure high performance and safe operation.
2.Low current system design also ensures operation safety.
3.Different temperature setting for various samples ensures complete sample digestion so as to get more accurate measuring data.
4.Adjust cooling module power according to sampling volume which improves drying performance to ensure dry gas into the detector.
5.Automatic leak check system to avoid operation mistakes and improve instrument performance, so as to ensure operation safety and instrument’s safety
6.Flow rate controlling system to avoid any effect caused by flow rate fluctuation which ensures accurate data.
7.TOC detector with 24 bits data solution extends monitoring range. Controlling system with 32bin processing technology greatly improves performance.

Product Show

Total Organic Carbon Analyzer with method of Wet chemical oxidation by UV

Technical Specification

Total Organic Carbon Analyzer with method of Wet chemical oxidation by UV

Sample measurement processing monitoring
Set different Name, concentration and sample volume
Real-time sample reaction
On-line AVG and RSD calculation of testing results

Total Organic Carbon Analyzer with method of Wet chemical oxidation by UV

Display and monitoring of sampling
Sampling volume real-time monitoring
Automatic sample draining monitoring
Real time display and monitoring for heating, cooling and temperature
Auto Switch of Sampling and Draining
Acidification operation by peristaltic pumps

Scanning Curves
Samples Curves shows in the same coordinate system for easy reading of repeatability

Parameter Setting Interface
Settings for heating and cooling temperature; acidification sampling and draining time; Basic setting for Pump, valve and temperature control
Press ”TC” Clean, the system will automatically start “ drain-add Sodium persulfate – Draining – Sampling -- Drainingining

Halogen Scrubber Design
Reduce Halogen and Moisture
Avoid any effect on the results caused by impurities

Four In One TIC Reactor Design
Helpful to remove inorganic carbon by acidification and heating digestion
Cooling function to remove moisture in carbon dioxide
Gas buffer design?? To avoid part broken caused by high pressure
High moisture removal function

High Temperature Pyrolysis system
Complete pyrolysis for samples with high temperature
Set different pyrolysis temperature for various samples

NDIR High Efficiency Detector
Detector with special surface treatment technology to ensure ideal performance
24 bit A/D Converter to ensure stable data, low noise, wide measurement range and high speed
32bin signal processing technology to ensure the instrument’s constant temperature function with 0.01℃ temperature tolerance.

Packaging & Shipping

Packing & Delivery
Packing Details: each set protected with pp film, then put into strong carton box with operation manul and vedio inside.
Delivery Details: 10-15 days after ordering.

Shipment Terms & Payment Terms
Main Shipping Terms:
1.Port to Port:  by air; by sea
2.Door to Door:  by air-express, including DHL, FedEx, TNT, EMS etc.

Main Payment Terms: T/T; Paypal; Western Union; Moneygram etc.Payment terms are different depending on different countries, Our company reserves the right to interpret.

Company Information

 A & E Lab (UK) Co.,Ltd.is a British company that has many years of manufacturing and selling wide range of scientific and laboratory instruments. Our main products include: UV Visible Spectropotometer, Visible Spectrophotometer, PCR-Cycler, Stirrer Hotplates, Shaker, Rocker, Block Heater, Mixers, etc. The goods have been exported to every country of the world with high quality and good service.

 

Main market: Domestic Market,South Asia,Southern Europe,Northern Europe,Central America,Western Europe,Eastern Asia,Mid East,Oceania,Africa,Southeast Asia,Eastern Europe,South America,North America.

 

Our mission is to develop and market products through distributors all over the world. To meet your requirement, our technical and supportive staffs will help you choose the most suitable products.

 

Please do not hesitate, A & E Lab products are worth a try!

Total Organic Carbon Analyzer with method of Wet chemical oxidation by UV

Our Services

 Certifications

Total Organic Carbon Analyzer with method of Wet chemical oxidation by UV

Customs Photos

Total Organic Carbon Analyzer with method of Wet chemical oxidation by UV

FAQ

Q: How about the warranty for your products?
A: All of our products have one year warranty. During the guarantee period, if there are any problem with our instrument, we will help you to solve it by sending pictures, videos or free spare parts until things get fixed. Out of guarantee, we will also help you solve the problem,but not including send free spare parts to your country.

Q: can you do OEM?
A: Yes, we can do OEM/ODM as you required.

Q: Can you offer the technical support, online or site training or other
A: We will offer technical support like operating manual, operating videos to support or provided training material of the detailed products you are interested in. If you have chance to come to Guangzhou, welcome to our office, we have samples here, and we can show you how to operate them.

Q: May I have a free sample? I need test your quality first.
A: We are regret to tell you that we could not offer free sample to our customers, which is our company rule. But if you agree, we can quote special price to better support you for trail order.